Putting Glass Walls on Pennsylvania Slaughterhouses So We Can See Behind Closed Doors from FAUN Friends Of Animals United
Eberly Poultry

Address: 1095 Mt. Airy Rd, Stevens, PA 17578
Establishment No.: p09965

USDA Inspection Report: 25 Oct 2011

Code: 03B01
Violation: 417.2(c)(4), 417.5(a)(3)

Citation: The Mechanically Separated Poultry temperature recorded before grinding is [redacted] degrees at 7:50pm. The next temperature recorded before grinding is [redacted] degrees at 9:55pm. CCP#1B states [redacted] The 7:50pm temperature did not meet the requirement of CCP#1B [redacted]. The frequency of once within the eight O'clock hour was not recorded. No regulatory control action was taken because the temperatures recorded after grinding is [redacted] degrees or less as per the CCP. At 10:30pm the Shift supervisor [redacted] was verbally notified of this noncompliance.

Regulation:

417.2(c)(4) List the procedures, and the frequency with which those procedures will be performed, that will be used to monitor each of the critical control points to ensure compliance with the critical limits

417.5(a)(3) Records documenting the monitoring of CCP’s and their critical limits, including the recording of actual times, temperatures, or other quantifiable values, as prescribed in the establishment’s HACCP plan; the calibration of process-monitoring instruments; corrective actions, including all actions taken in response to a deviation; verification procedures and results; product code(s), product name or identity, or slaughter production lot. Each of these records shall include the date the record was made.

 

Next Report: USDA Inspection Report: 4 Nov 2011
Previous Report: USDA Inspection Report: 25 Oct 2011

Return to: Eberly Poultry