Putting Glass Walls on Pennsylvania Slaughterhouses So We Can See Behind Closed Doors from FAUN Friends Of Animals United
Eberly Poultry

Address: 1095 Mt. Airy Rd, Stevens, PA 17578
Establishment No.: p09965

USDA Inspection Report: 16 Aug 2010

Code: 06D01
Violation: 416.1, 416.2(d), 416.4(d)

Citation: At 1440 Hr. while conducting inspections in the cut-up department, I observed dripping condensate from the overhead cooling unit. The water was coming off the drip pan that had a hole in it. It also had condensate dripping from the overhead area where the fan does not operate. I did not observe any condensate drip onto product or onto food contact surfaces. I notified [redacted] of the non-compliance at 1455 Hr. This is a violation of 9 CFR 416.1; 416.2(d); 416.4(d).

Regulation:

416.1 Each official establishment must be operated and maintained in a manner sufficient to prevent the creation of insanitary conditions and to ensure that product is not adulterated.

416.2(d) Ventilation. Ventilation adequate to control odors, vapors, and condensation to the extent necessary to prevent adulteration of product and the creation of insanitary conditions must be provided.

416.4(d) Product must be protected from adulteration during processing, handling, storage, loading, and unloading at and during transportation from official establishments.

 

Next Report: USDA Inspection Report: 18 Aug 2010
Previous Report: USDA Inspection Report: 10 Aug 2010

Return to: Eberly Poultry
Return to: Pennsylvania Slaughterhouses
Return to: Slaughterhouses